{"id":5131,"date":"2026-10-27T16:34:46","date_gmt":"2026-10-27T08:34:46","guid":{"rendered":"https:\/\/www.pandamechvehicle.com\/?p=5131"},"modified":"2026-10-30T11:01:34","modified_gmt":"2026-10-30T03:01:34","slug":"cement-powder-segregation-bulk-tanker","status":"publish","type":"post","link":"https:\/\/www.pandamechvehicle.com\/fr\/cement-powder-segregation-bulk-tanker\/","title":{"rendered":"Le ciment en vrac se s\u00e9pare-t-il pendant le transport en citerne ?"},"content":{"rendered":"\n<style>\n.pm-cement-guide{color:#242b34;font-family:inherit;font-size:17px;line-height:1.75;overflow-wrap:anywhere}\n.pm-cement-guide .pm-intro,.pm-cement-guide .pm-section,.pm-cement-guide .pm-nav{box-sizing:border-box;padding:22px;margin:0 0 24px;border:1px solid #e0e4e8;border-radius:16px;background:#fff}\n.pm-cement-guide .pm-section{border-top:4px solid #4b5563;box-shadow:0 3px 12px rgba(20,30,40,.035);scroll-margin-top:100px}\n.pm-cement-guide .pm-intro,.pm-cement-guide .pm-nav{background:#f6f7f8}\n.pm-cement-guide h2{font-size:30px;line-height:1.3;margin:0 0 18px;color:#202832}\n.pm-cement-guide h3{font-size:24px;line-height:1.35;margin:26px 0 12px;color:#202832}\n.pm-cement-guide p{margin:0 0 16px}.pm-cement-guide p:last-child{margin-bottom:0}\n.pm-cement-guide ul,.pm-cement-guide ol{margin:12px 0 20px;padding-left:24px}.pm-cement-guide li{margin:0 0 12px}\n.pm-cement-guide a{color:#1f4e6a;text-decoration:underline;text-underline-offset:3px}.pm-cement-guide a:focus-visible,.pm-cement-guide summary:focus-visible{outline:3px solid #80551c;outline-offset:4px}\n.pm-cement-guide .pm-nav summary{cursor:pointer;font-weight:700}.pm-cement-guide .pm-nav ul{margin-bottom:0}\n.pm-cement-guide .pm-table{overflow-x:auto;margin:20px 0;overscroll-behavior-inline:contain}\n.pm-cement-guide table{border-collapse:collapse;width:100%;min-width:620px;font-size:inherit;line-height:1.6}\n.pm-cement-guide th,.pm-cement-guide td{padding:13px 15px;border:1px solid #d9dee4;text-align:left;vertical-align:top}\n.pm-cement-guide th{background:#edf0f3;color:#202832}.pm-cement-guide tbody tr:nth-child(even){background:#fafbfc}\n.pm-cement-guide .pm-media{margin:24px 0}.pm-cement-guide .pm-media img{display:block;width:100%;height:auto;border-radius:10px}\n.pm-cement-guide .pm-cta{display:inline-block;background:#374151;color:#fff;padding:12px 20px;border-radius:8px;text-decoration:none;font-weight:700}\n@media(max-width:767px){.pm-cement-guide{font-size:16px}.pm-cement-guide .pm-intro,.pm-cement-guide .pm-section,.pm-cement-guide .pm-nav{padding:18px;margin-bottom:18px;border-radius:12px}.pm-cement-guide .pm-section{border-top-width:3px}.pm-cement-guide h2{font-size:24px}.pm-cement-guide h3{font-size:20px}.pm-cement-guide th,.pm-cement-guide td{padding:11px 12px}.pm-cement-guide .pm-media{margin:20px 0}}\n<\/style>\n<article class=\"pm-cement-guide\">\n<div class=\"pm-intro\"><p><strong>Yes. Bulk cement can segregate when particles move apart during loading, road transport or pneumatic unloading. Whether that changes the delivered cement\u2019s quality depends on the powder, the handling conditions and the measured variation.<\/strong><\/p><p>Cement powder segregation in a bulk tanker means an uneven distribution of particle sizes or components. It is different from the powder simply settling into less space. For a questionable delivery, start with the cement grade and compare samples along the delivery path. A rough road, a lower powder level or slow unloading alone does not establish that the cement has separated.<\/p><\/div><nav aria-label=\"Article contents\" class=\"pm-nav\"><details><summary>In this guide<\/summary><ul><li><a href=\"#materials\">What Does Segregation Mean in a Cement Tanker?<\/a><\/li><li><a href=\"#stages\">When Can Cement Powder Separate During Delivery?<\/a><\/li><li><a href=\"#symptoms\">Is It Segregation, Settling, Caking or Contamination?<\/a><\/li><li><a href=\"#sampling\">How Can You Test Whether a Delivery Has Segregated?<\/a><\/li><li><a href=\"#prevention\">How Can You Reduce Segregation Risk in Practice?<\/a><\/li><li><a href=\"#decision\">What Should You Do if Cement Uniformity Is in Doubt?<\/a><\/li><li><a href=\"#faq\">More Questions About Bulk Cement Segregation<\/a><\/li><\/ul><\/details><\/nav><section class=\"pm-section\" id=\"materials\"><h2>What Does Segregation Mean in a Cement Tanker?<\/h2><p><strong>Segregation means that different parts of the load no longer have the same particle-size distribution or composition.<\/strong> The important question is whether the material leaving the tanker still meets the agreed cement specification throughout delivery.<\/p><p>Dry cement contains a range of particle sizes. A powder blend may also contain components with different sizes, shapes or densities. When the particles can move relative to one another, those differences can produce uneven regions. Fine particles do not always move downward: air moving through the powder can change the direction of separation.<\/p><p>Identify the cargo before choosing a remedy:<\/p><div class=\"pm-table\"><table><thead><tr><th scope=\"col\">Cargo<\/th><th scope=\"col\">What could change<\/th><th scope=\"col\">What to investigate<\/th><\/tr><\/thead><tbody><tr><td>Ordinary portland cement<\/td><td>The distribution of fine and coarse particles<\/td><td>Compare particle size and the quality properties relevant to the complaint.<\/td><\/tr><tr><td>Blended cement<\/td><td>Particle size and, where components separate differently, the local blend composition<\/td><td>Check both size distribution and a composition measurement suited to that blend.<\/td><\/tr><tr><td>Dry-mixed mortar<\/td><td>The distribution of sand, binder and other ingredients<\/td><td>Use a mortar-specific transport and uniformity assessment.<\/td><\/tr><\/tbody><\/table><\/div><p><strong>Dry-mixed mortar is a different cargo from finished cement powder.<\/strong> Published research on <a href=\"https:\/\/www.scientific.net\/AMR.542-543.1100\" rel=\"nofollow noopener\" target=\"_blank\">dry-mixed mortar truck segregation<\/a> concerns a mixture whose ingredients can respond differently during air-assisted discharge. Its proposed equipment solution should not be treated as a standard requirement for every cement tanker.<\/p><\/section><section class=\"pm-section\" id=\"stages\"><h2>When Can Cement Powder Separate During Delivery?<\/h2><p><strong>Separation can develop while the tanker is filled, while a mobile powder bed is disturbed, or while material enters and leaves the receiving silo.<\/strong> Check the whole transfer path before blaming the journey.<\/p><h3>Can Loading Create an Uneven Load?<\/h3><p><strong>Yes. A falling stream can form a pile in which particle groups collect in different places.<\/strong> In sifting segregation, fines pass between coarser particles near the impact zone, while coarse particles roll outward. Air currents can also carry very fine material away from that zone.<\/p><p>These are different mechanisms. <a href=\"https:\/\/jenike.com\/handling-segregation-gone-wind\/\" rel=\"nofollow noopener\" target=\"_blank\">Jenike &amp; Johanson\u2019s explanation of powder segregation<\/a> distinguishes sifting, fluidization and dusting. Identifying the mechanism helps determine whether to change the filling arrangement, air handling or subsequent discharge pattern.<\/p><h3>Does Road Vibration Always Damage Cement?<\/h3>\n<figure class=\"wp-block-image size-full\" data-image-id=\"P5131-ADD02\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.pandamechvehicle.com\/wp-content\/uploads\/2026\/10\/cement-tanker-running-gear.webp\" alt=\"Does Road Vibration Always Damage Cement?\" width=\"1200\" height=\"900\" class=\"wp-image-5672\" style=\"display:block;max-width:100%;height:auto;margin:20px auto\" loading=\"lazy\" srcset=\"https:\/\/www.pandamechvehicle.com\/wp-content\/uploads\/2026\/10\/cement-tanker-running-gear.webp 1200w, https:\/\/www.pandamechvehicle.com\/wp-content\/uploads\/2026\/10\/cement-tanker-running-gear-300x225.webp 300w, https:\/\/www.pandamechvehicle.com\/wp-content\/uploads\/2026\/10\/cement-tanker-running-gear-1024x768.webp 1024w, https:\/\/www.pandamechvehicle.com\/wp-content\/uploads\/2026\/10\/cement-tanker-running-gear-768x576.webp 768w, https:\/\/www.pandamechvehicle.com\/wp-content\/uploads\/2026\/10\/cement-tanker-running-gear-16x12.webp 16w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/figure><p><strong>No. Vibration can promote particle rearrangement, but a particular journey\u2019s effect must be established from the material and delivery results.<\/strong> A compacted load is not automatically a segregated load.<\/p><p>Do not assign a universal rejection distance or driving-time limit. Compare equivalent loads from the same source and grade, with loading and unloading conditions recorded. Otherwise, a change at the loading silo may be mistaken for a road effect.<\/p><h3>Can Pneumatic Unloading or the Receiving Silo Matter?<\/h3><p><strong>Yes. Air and the receiving silo\u2019s filling and discharge patterns can alter the distribution observed downstream.<\/strong> During fluidization segregation, coarse particles can settle as they lose air while finer material remains aerated higher in the bed.<\/p><p><a href=\"https:\/\/jenike.com\/unique-flow-challenges-cement-handling\/\" rel=\"nofollow noopener\" target=\"_blank\">Jenike &amp; Johanson\u2019s cement-handling guidance<\/a> describes fluidization and dusting mechanisms. This is why a sample from the silo outlet should be compared with material entering the silo, rather than used by itself to judge the tanker.<\/p><\/section><section class=\"pm-section\" id=\"symptoms\"><h2>Is It Segregation, Settling, Caking or Contamination?<\/h2><p><strong>Look for a change in particle distribution or composition when investigating segregation. A lower powder level, lumps or a color change calls for a different first check.<\/strong> These problems can occur together, so keep the observations separate.<\/p><div class=\"pm-table\"><table><thead><tr><th scope=\"col\">Observation<\/th><th scope=\"col\">Possible explanation<\/th><th scope=\"col\">First useful check<\/th><\/tr><\/thead><tbody><tr><td>Powder occupies less space after travel<\/td><td>Air has escaped and the powder has settled<\/td><td>Compare cargo mass and its aeration state; inspect for other changes.<\/td><\/tr><tr><td>Hard lumps or damp deposits<\/td><td>Moisture exposure and possible hydration<\/td><td>Investigate seals, previous cleaning and the air supply.<\/td><\/tr><tr><td>Unfamiliar color or foreign particles<\/td><td>Previous-cargo residue, wrong grade or another contaminant<\/td><td>Trace loading records, seals and previous cargo.<\/td><\/tr><tr><td>Repeatable differences between discharge portions<\/td><td>Particle-size or component segregation<\/td><td>Test separate portions using the same laboratory method.<\/td><\/tr><\/tbody><\/table><\/div><p>Settling increases bulk density when the same mass occupies less volume. It does not, by itself, show that one ingredient has moved away from another. Similarly, uneven discharge can result from restricted airflow or a blocked outlet. Our <a href=\"https:\/\/www.pandamechvehicle.com\/cement-tanker-engineering\/cement-tanker-aeration-system\/\">cement tanker aeration guide<\/a> explains those flow problems.<\/p><div class=\"pm-media\"><img loading=\"lazy\" alt=\"Is It Segregation, Settling, Caking or Contamination?\" decoding=\"async\" height=\"900\" loading=\"lazy\" src=\"https:\/\/www.pandamechvehicle.com\/wp-content\/uploads\/2026\/10\/p5131-i03-size-optimized.webp\" width=\"1200\"\/><\/div><\/section><section class=\"pm-section\" id=\"sampling\"><h2>How Can You Test Whether a Delivery Has Segregated?<\/h2><p><strong>Compare representative source material with separately retained discharge portions, then check the receiving silo if the variation appears downstream.<\/strong> Agree on the sampling plan with the cement supplier\u2019s quality team before the trial.<\/p><h3>Sample the Delivery in Stages<\/h3><p><strong>Keep the portions separate until they have been tested.<\/strong> A single combined sample can hide a change between the beginning and end of unloading.<\/p><ol><li><strong>Establish the source reference.<\/strong> Obtain a representative retained sample from the same batch and loading period. Record the grade, batch, loading silo, tanker and previous cargo. A certificate gives useful batch information; the retained material allows direct comparison.<\/li><li><strong>Collect discharge portions.<\/strong> As a diagnostic starting point, retain early, middle and late portions separately. Use transferred-mass positions where available, because equal time intervals may represent unequal quantities. Have the quality team set the required increments and sample quantities.<\/li><li><strong>Record the transfer conditions.<\/strong> Log discharge sequence, interruptions, operating readings and receiving-silo identity. Use a designed sampling point operated by trained staff. Do not loosen a pressurized hose, valve or manhole to obtain a sample.<\/li><li><strong>Keep a traceable sample set.<\/strong> Seal and label each container promptly. Keep duplicate material for repeat or independent testing. Where a smaller laboratory portion is needed, use suitable sample-reduction equipment rather than scooping only from the top.<\/li><li><strong>Compare the receiving side.<\/strong> If tanker discharge portions are consistent but later silo samples vary, investigate silo filling, existing stock and withdrawal. Mixing with older stock makes a before-and-after comparison harder to interpret.<\/li><\/ol><p><a href=\"https:\/\/store.astm.org\/c0183_c0183m-25e01.html\" rel=\"nofollow noopener\" target=\"_blank\">ASTM C183\/C183M<\/a> addresses sampling and the amount of testing for manufactured hydraulic cement offered for sale. Use the method required by the purchase specification for acceptance. The early\u2013middle\u2013late comparison above is an investigation plan, rather than a quoted sampling frequency from that standard.<\/p><div class=\"pm-media\"><img loading=\"lazy\" alt=\"How Can You Test Whether a Delivery Has Segregated?\" decoding=\"async\" height=\"900\" loading=\"lazy\" src=\"https:\/\/www.pandamechvehicle.com\/wp-content\/uploads\/2026\/10\/cement-delivery-separate-retained-samples.webp\" width=\"1200\"\/><\/div><h3>Match the Test to the Suspected Change<\/h3><p><strong>Measure particle size for size separation, and use a blend-specific composition test when the concern is ingredient proportion.<\/strong> Ask the laboratory to use consistent sample preparation and report its measurement repeatability.<\/p><p>Laser diffraction or appropriate sieve-residue tests can compare particle-size results. Blaine fineness measures specific surface area; it does not describe the whole size distribution. Malvern Panalytical explains why <a href=\"https:\/\/www.malvernpanalytical.com\/en\/learn\/knowledge-center\/whitepapers\/wp120509reducecostcementautoproccontrol\" rel=\"nofollow noopener\" target=\"_blank\">cements with the same Blaine value can have different particle-size distributions<\/a>. For blended cement, the producer\u2019s validated chemical or mineralogical method must distinguish the relevant ingredients. Similar ingredients can have overlapping chemical signatures, so a general chemistry result may not yield their proportions directly.<\/p><p>If delivery performance is the issue, add the specified setting or strength tests. <a href=\"https:\/\/jenike.com\/services\/bulk-material-testing-segregation\/\" rel=\"nofollow noopener\" target=\"_blank\">Bulk-material segregation testing<\/a> can help identify separation tendencies and compare particle-size fractions when recurring variation needs deeper investigation.<\/p><p>Consider a hypothetical 30-tonne delivery split into three equal 10-tonne portions. Suppose a validated assay measures one blend component at 18%, 20% and 22%. The mass-weighted average is <strong>(10 \u00d7 18 + 10 \u00d7 20 + 10 \u00d7 22) \u00f7 30 = 20%<\/strong>. The average matches 20%, while individual portions differ. Whether those differences are acceptable depends on the product requirements and test precision.<\/p><\/section><section class=\"pm-section\" id=\"prevention\"><h2>How Can You Reduce Segregation Risk in Practice?<\/h2><p><strong>Start with a uniform source product, control transfers and use a discharge setup matched to the powder and receiving silo.<\/strong> Change the stage that testing identifies, rather than adding agitation everywhere.<\/p><ul><li><strong>At loading:<\/strong> use the intended enclosed loading connection and dust-control arrangement. Review an excessive free fall or an uneven filling pattern with the loading-system supplier when source-to-load testing shows a problem.<\/li><li><strong>During transport:<\/strong> maintain seals and protect the cargo from moisture and incompatible residues. Record unusual delays and route conditions so repeated complaints can be compared meaningfully.<\/li><li><strong>During unloading:<\/strong> keep aeration zones and discharge equipment serviceable. Use the approved operating sequence and air supply for the cargo. More air or pressure is not a reliable mixing remedy.<\/li><li><strong>At the receiving silo:<\/strong> keep the vent filter and filling system in working order. If variation begins there, review inlet arrangement, existing stock and discharge flow with the silo supplier.<\/li><\/ul><p>Our <a href=\"https:\/\/www.pandamechvehicle.com\/products\/pneumatic-dry-bulk-trailer\/\">pneumatic dry bulk trailers<\/a> are configured around cargo, tank geometry and unloading conditions. <strong>Aeration helps powder leave the tanker; it is not a substitute for a validated blending process.<\/strong> Likewise, several outlets do not necessarily mean separate cargo chambers. Keep different grades separate using a confirmed compartment and discharge arrangement.<\/p><div class=\"pm-media\"><img loading=\"lazy\" alt=\"How Can You Reduce Segregation Risk in Practice?\" decoding=\"async\" height=\"900\" loading=\"lazy\" src=\"https:\/\/www.pandamechvehicle.com\/wp-content\/uploads\/2026\/10\/cement-tanker-closed-silo-connection.webp\" width=\"1200\"\/><\/div><\/section><section class=\"pm-section\" id=\"decision\"><h2>What Should You Do if Cement Uniformity Is in Doubt?<\/h2><p><strong>If there is a credible quality discrepancy, keep the affected material identifiable and arrange supplier-led testing before mixing it with accepted stock.<\/strong> Record where the difference was found and retain the related samples and delivery documents.<\/p><p>If unloading has started, use the normal safe shutdown procedure when a hold is needed, then identify the material already transferred. The supplier\u2019s quality team should decide acceptance, return or an authorized reprocessing route from the results. Adding water, driving extra laps or prolonged aeration is not a quality correction.<\/p><p>Bulk cement segregation during tanker delivery is possible. The useful decision comes from identifying the material, locating where variation begins and testing it against the relevant requirements.<\/p><p>For an equipment review, send us the cement grade, target payload, current air supply and receiving-silo details through our contact form. These inputs help us discuss a suitable tanker configuration.<\/p><p><a class=\"pm-cta\" href=\"https:\/\/www.pandamechvehicle.com\/contact-us\/\">Get a Tanker Configuration<\/a><\/p><\/section><section class=\"pm-section\" id=\"faq\"><h2>More Questions About Bulk Cement Segregation<\/h2><h3>Should a 500 km Cement Delivery Be Rejected Because of the Distance?<\/h3><p><strong>No. Distance alone does not establish a quality failure.<\/strong> Compare the delivered material with the batch reference and purchase requirements. If one route repeatedly produces differences, investigate that route with equivalent cargo and controlled loading and unloading conditions.<\/p><h3>Does Cement That Settles Overnight Need Remixing?<\/h3><p><strong>A lower powder level alone does not justify remixing.<\/strong> First distinguish air loss and settling from moisture, contamination or measured composition changes. Keep the cargo protected and use the normal discharge procedure if its quality remains acceptable.<\/p><h3>Can the First Half of a Load Differ From the Second Half?<\/h3><p><strong>Yes, if the load or discharge stream is nonuniform.<\/strong> This matters when splitting one load between two receiving silos. Retain samples linked to each delivered quantity; one whole-load composite may conceal differences between the two deliveries.<\/p><h3>Can Bulk Density Alone Confirm Segregation?<\/h3><p><strong>No. Bulk density also changes with aeration and packing.<\/strong> Compare measurements made with the same preparation method, then use particle-size or composition testing to investigate the suspected separation.<\/p><h3>Can the Driver Add Air to Blend Cement Before Unloading?<\/h3><p><strong>Do not use extra aeration as an improvised blending treatment.<\/strong> It can change powder behavior without establishing uniformity. Use the approved discharge sequence; hold a disputed load for the supplier\u2019s quality decision rather than changing pressure to treat it.<\/p><\/section><\/article>\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Should a 500 km Cement Delivery Be Rejected Because of the Distance?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. Distance alone does not establish a quality failure. Compare the delivered material with the batch reference and purchase requirements. If one route repeatedly produces differences, investigate that route with equivalent cargo and controlled loading and unloading conditions.\"}}, {\"@type\": \"Question\", \"name\": \"Does Cement That Settles Overnight Need Remixing?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"A lower powder level alone does not justify remixing. First distinguish air loss and settling from moisture, contamination or measured composition changes. Keep the cargo protected and use the normal discharge procedure if its quality remains acceptable.\"}}, {\"@type\": \"Question\", \"name\": \"Can the First Half of a Load Differ From the Second Half?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes, if the load or discharge stream is nonuniform. This matters when splitting one load between two receiving silos. Retain samples linked to each delivered quantity; one whole-load composite may conceal differences between the two deliveries.\"}}, {\"@type\": \"Question\", \"name\": \"Can Bulk Density Alone Confirm Segregation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. Bulk density also changes with aeration and packing. Compare measurements made with the same preparation method, then use particle-size or composition testing to investigate the suspected separation.\"}}, {\"@type\": \"Question\", \"name\": \"Can the Driver Add Air to Blend Cement Before Unloading?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Do not use extra aeration as an improvised blending treatment. It can change powder behavior without establishing uniformity. Use the approved discharge sequence; hold a disputed load for the supplier\u2019s quality decision rather than changing pressure to treat it.\"}}]}<\/script>\n","protected":false},"excerpt":{"rendered":"<p>Yes. Bulk cement can segregate when particles move apart during loading, road transport or pneumatic unloading. Whether that changes the delivered cement\u2019s quality depends on the powder, the handling conditions and the measured variation. Cement powder segregation in a bulk tanker means an uneven distribution of particle sizes or components. It is different from the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":5156,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-5131","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.pandamechvehicle.com\/fr\/wp-json\/wp\/v2\/posts\/5131","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pandamechvehicle.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pandamechvehicle.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pandamechvehicle.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pandamechvehicle.com\/fr\/wp-json\/wp\/v2\/comments?post=5131"}],"version-history":[{"count":5,"href":"https:\/\/www.pandamechvehicle.com\/fr\/wp-json\/wp\/v2\/posts\/5131\/revisions"}],"predecessor-version":[{"id":5673,"href":"https:\/\/www.pandamechvehicle.com\/fr\/wp-json\/wp\/v2\/posts\/5131\/revisions\/5673"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.pandamechvehicle.com\/fr\/wp-json\/wp\/v2\/media\/5156"}],"wp:attachment":[{"href":"https:\/\/www.pandamechvehicle.com\/fr\/wp-json\/wp\/v2\/media?parent=5131"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pandamechvehicle.com\/fr\/wp-json\/wp\/v2\/categories?post=5131"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pandamechvehicle.com\/fr\/wp-json\/wp\/v2\/tags?post=5131"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}